Mô tả
| Functional principle | Photoelectric proximity sensor |
| Functional principle detail | Background suppression |
| Sensing range | |
| Sensing range min. | 30 mm |
| Sensing range max. | 1,600 mm |
| Adjustable switching threshold for background suppression | 180 mm … 1,600 mm |
| Reference object | Object with 90% remission (based on standard white, DIN 5033) |
| Minimum distance between set sensing range and background (black 6% / white 90%) | 40 mm, at a distance of 600 mm |
| Recommended sensing range for the best performance | 200 mm … 600 mm |
| Emitted beam | |
| Light source | PinPoint LED |
| Type of light | Visible red light |
| Shape of light spot | Point-shaped |
| Light spot size (distance) | Ø 7 mm (700 mm) |
| Maximum dispersion of the emitted beam around the standardized transmission axis (squint angle) | < +/- 1.0° (at Ta = +23 °C) |
| Key LED figures | |
| Normative reference | EN 62471:2008-09 | IEC 62471:2006, modified |
| LED risk group marking | Free group |
| Wave length | 635 nm |
| Average service life | 100,000 h at Ta = +25 °C |
| Adjustment | |
| Teach-Turn adjustment | BluePilot: For setting the sensing range |
| IO-Link | For configuring the sensor parameters and Smart Task functions |
| Indication | |
| LED blue | BluePilot: sensing range indicator |
| LED green | Operating indicator |
| Static on: power on | |
| Flashing: IO-Link mode | |
| LED yellow | Status of received light beam |
| Static on: object present | |
| Static off: object not present | |
| Supply voltage UB | 10 V DC … 30 V DC 1) |
| Ripple | ≤ 5 Vpp |
| Usage category | DC-12 (According to EN 60947-5-2) |
| DC-13 (According to EN 60947-5-2) | |
| Current consumption | ≤ 30 mA, without load. At UB = 24 V |
| Protection class | III |
| Digital output | |
| Number | 2 (Complementary) |
| Type | Push-pull: PNP/NPN |